| Type | Thickness (mm) | Material | Prestressing | Sandbl. |
|---|
Note: Borosilicate glass and glass ceramics are listed for convenience. EN 16612:2019 Table 4 (ksp) only covers float, drawn sheet, patterned and wired glass; for other types ksp = 1.0 is assumed (same as float glass).
↧ Line Load — Barrier / Balustrade
EN 1991-1-1 Table 6.12 barrier loads (e.g. 0.5–1.0 kN/m for residential/office). Converted to equivalent UDL via moment equivalence — simply supported: q = 8·F·h·(a−h)/a³; cantilever: q = 2·F·h/a². Set F = 0 to skip line load combinations.
⚙ Consequence Class (γ factors)
EN 16612:2019 Table 2. Use CC1 for infill panels that only carry wind/snow and self-weight. Use CC2 for glass that is part of the main building structure or carries personnel/barrier loads.
◢ Installation
90° = vertical glazing, 0° = horizontal roof. Self-weight is projected as g·cos(θ).
⇆ Deflection Limits
EN 16612:2019 §9.1.4: default limit is span/65 or 50 mm, whichever is lower.